Select Currency
Translate this page

ESTIMATION OF ORGAN EQUIVALENT AND EFFECTIVE DOSES FROM DIAGNOSTIC X-RAY

Format: MS WORD  |  Chapter: 1-5  |  Pages: 75  |  4160 Users found this project useful  |  Price NGN5,000

  DOWNLOAD THE FULL PROJECT

ESTIMATION OF ORGAN EQUIVALENT AND EFFECTIVE DOSES FROM DIAGNOSTIC X-RAY

 

ABSTRACT

The radiation dose received by the patient during the radiological examination is essential to prevent risks of exposure. The aim of this work is to study organ equivalent and effective dose s for common diagnostic radiographic examinations at General hospital Dutsin-Ma local Government Area, Katsina State, Nigeria. We estimated the entrance surface dose received by patients undergoing diagnostic X-ray examinations, including the entrance surface dose and effective doses for 20 patients in six types of X-ray examinations. The entrance surface dose was determined indirectly via measurements and from knowledge of X-ray output factors. We entered measurement parameters such as X-ray dose output, backscatter factor, and focus to skin distance as well as physical parameters such as mAs and kV in mathematical model. The mean for entrance surface doses and effective doses for chest (PA, AP), abdomen (AP) and skull (AP, Lateral) are 0.2432 mGy, 0.2857 mGy, 0.6331 mGy, 0.7553 mGy, 0.3220 mGy and 0.01216 mSv, 0.01428mSv, 0.07597 mSv, 0.00755 mSv and 0.00322 mSv respectively. The results obtained were compared with those published by some national and international agencies. The entrance surface dose and effective dose reported in this study are generally lower than the comparable reference dose values published in the literature. On the basis of the result obtained in this study, one can conclude that proper use of radiological parameter such as the large distance between patient and X-ray source, high tube potential and low tube current can significantly reduce the absorbed dose which has been shown in this work. When technical and clinical factors are optimized or properly used, patient doses will reduce substantially. Further studies are required for minimization of radiation doses to sensitive organs.

 

CHAPTER ONE

INTRODUCTION

1.1 Background of the study

Nowadays human organ imaging is performed by different systems and methods. As the new diagnostic methods including conventional radiography, fluoroscopy, and computed tomography (CT) procedures will continue to provide tremendous benefit to modern health care, radiography is expected to be in progress as well, because it is still a powerful tool with enough benefit for the patients undoubtedly. Therefore, patients’ exposure to radiation has been increased all over the world due to this radiography (The 2007 Recommendations of the International Commission on Radiological Protection, ICRP publication 103, 2007; European Commission, European Guidance on Estimating Population Doses from Medical X-Ray Procedures. Radiation Protection N.154, 2008; Fazel et al., 2009; Hart et al, 2010; United Nations Scientific Committee Effects Atomic Radiation, 2010). A wide range of radiation absorbed doses is delivered to patients by the various diagnostic imaging modalities that use ionizing radiation. Even though these procedures are assumed to produce a net benefit, the potential for radiation-induced injuries to the patient exists (The AAPM/RSNA Physics Tutorial for Residents Typical Patient Radiation Doses in Diagnostic Radiology 1, 1999). Since using ionising x-rays is associated with some risk of developing cancer, the basic radiation protection concept or philosophy ALARA states that all exposures must always be kept ‘As Low As Reasonably Achievable’ (National Council on Radiation Protection and Measurements, 1990).

So, the knowledge of the radiation dose received by the patient during the radiological examination is essential to prevent risks of exposures that involve a great number of people. Various indicators are used to estimate detriment from cancer and genetic effects of radiation. According to ICRP 60, the basic quantity associated with the risk of deleterious effects on health is the effective dose that is the valuable and central quantity for dose limitation in the field of radiological protection of the patient (International Commission on Radiological Protection, 1991). This dose descriptor is being increasingly used to determine the quantity of radiation dose received by patient undergoing diagnostic x-ray examinations (Brenner and Huda, 2008; Kharita et al., 2010; Mettler et al, 2008; Osei and Darko, 2013; Shahbazi-Gahrouei and Baradaran-Ghahfarokhi, 2013; Teles et al., 2013). Whereas effective dose (ED) is affected by patient structure and radiological method, as such, the calculation of this quantity is of utmost importance. Because it is almost impossible to directly measure effective dose during clinical procedures, it must be determined indirectly.

In general, indirect estimate of effective dose starts from incident air kerma (Ka,i) measurement as input parameters and uses dedicated conversion coefficients (European Commission, European Guidance on Estimating Population Doses from Medical X-ray Procedures, Radiation Protection N.154, 2008; International Atomic Energy Agency, 2007; International Commission Radiation Units, 2005). Entrance skin dose (ESD) is also an important parameter in accessing the dose received by a patient in a single radiographic exposure. The European Union has identified this physical quantity as one to be monitored as a diagnostic reference level in the hopes of optimizing patient dose (Bushong, 2001 and ICRP, 1991).

  DOWNLOAD THE FULL PROJECT

ESTIMATION OF ORGAN EQUIVALENT AND EFFECTIVE DOSES FROM DIAGNOSTIC X-RAY

Not The Topic You Are Looking For?



For Quick Help Chat with Us Now!

+234 813 292 6373

+233 55 397 8005


HOW TO GET THE COMPLETE PROJECT ON ESTIMATION OF ORGAN EQUIVALENT AND EFFECTIVE DOSES FROM DIAGNOSTIC X-RAY INSTANTLY

  • Click on the Download Button above.
  • Select any option to get the complete project immediately.
  • Chat with Our Instant Help Desk on +234 813 292 6373 for further assistance.
  • All projects on our website are well researched by professionals with high level of professionalism.

Here's what our amazing customers are saying

Abdulrazak Bello Marsha
Usman Dan fodio University
It was quite a better guide for project and paper presentation purpoting. Many thanks.
Average
Oluchi From Michael Opara University
If you are a student and you have not used iprojectmaster materials, you are missing big time! iprojectmaster is the BEST
Excellent
Abdul Mateen Iddrisu
UDS
At first I taught is a site full of fraudsters until I saw my project in my Gmail after my payment.. THANK YOU IPROJECTMASTER and May God the almighty bless u guys abundantly
Excellent
MATTHEW NGBEDE
Ahmadu Bello University
I wish I knew you guys when I wrote my first degree project, it took so much time and effort then. Now, with just a click of a button, I got my complete project in less than 15 minutes. You guys are too amazing!
Excellent
Ibrahim Muhammad Muhammad
Usmanu danfodiyo university, sokoto
It's a site that give researcher student's to gain access work,easier,affordable and understandable. I appreciate the iproject master teams for making my project work fast and available .I will surely,recommend this site to my friends.thanks a lot..!
Excellent
Merry From BSU
I am now a graduate because of iprojectmaster.com, God Bless you guys for me.
Excellent
Peace From Unilag
I cried not knowing how to go about my project but the day i searched online and saw iprojectmaster, i called and got my full project in less than 15minutes, i was shocked!
Excellent
Gbadamosi Solomon Oluwabunmi
Lasu
Swift delivery within 9 minutes of payment. Thank you project master
Excellent
Stancy M
Abia State University, Uturu
I did not see my project topic on your website so I decided to call your customer care number, the attention I got was epic! I got help from the beginning to the end of my project in just 3 days, they even taught me how to defend my project and I got a 'B' at the end. Thank you so much iprojectmaster, infact, I owe my graduating well today to you guys...
Excellent
Joseph M. Yohanna
Thanks a lot, am really grateful and will surely tell my friends about your website.
Excellent

FREQUENTLY ASKED QUESTIONS

How do I get this complete project on ESTIMATION OF ORGAN EQUIVALENT AND EFFECTIVE DOSES FROM DIAGNOSTIC X-RAY?

Simply click on the Download button above and follow the procedure stated.

I have a fresh topic that is not on your website. How do I go about it?

How fast can I get this complete project on ESTIMATION OF ORGAN EQUIVALENT AND EFFECTIVE DOSES FROM DIAGNOSTIC X-RAY?

Within 15 minutes if you want this exact project topic without adjustment

Is it a complete research project or just materials?

It is a Complete Research Project i.e Chapters 1-5, Abstract, Table of Contents, Full References, Questionnaires / Secondary Data

What if I want to change the case study for ESTIMATION OF ORGAN EQUIVALENT AND EFFECTIVE DOSES FROM DIAGNOSTIC X-RAY, What do i do?

Chat with Our Instant Help Desk Now: +234 813 292 6373 and you will be responded to immediately

How will I get my complete project?

Your Complete Project Material will be sent to your Email Address in Ms Word document format

Can I get my Complete Project through WhatsApp?

Yes! We can send your Complete Research Project to your WhatsApp Number

What if my Project Supervisor made some changes to a topic i picked from your website?

Call Our Instant Help Desk Now: +234 813 292 6373 and you will be responded to immediately

Do you assist students with Assignment and Project Proposal?

Yes! Call Our Instant Help Desk Now: +234 813 292 6373 and you will be responded to immediately

What if i do not have any project topic idea at all?

Smiles! We've Got You Covered. Chat with us on WhatsApp Now to Get Instant Help: +234 813 292 6373

How can i trust this site?

We are well aware of fraudulent activities that have been happening on the internet. It is regrettable, but hopefully declining. However, we wish to reinstate to our esteemed clients that we are genuine and duly registered with the Corporate Affairs Commission as "PRIMEDGE TECHNOLOGY". This site runs on Secure Sockets Layer (SSL), therefore all transactions on this site are HIGHLY secure and safe!